Owners of the 1992 Ford F-350 have reported 11 fuel system problems to NHTSA, 21% of all complaints about this model year.
Where owners named a specific part, the most common were storage (7) and delivery (2).
The typical report came at around 88,000 miles, and complaints were filed between August 1997 and August 2017.
These fuel system complaints include 2 fires.
For comparison, the 2005 F-350 has the most fuel system complaints of any year, with 36.
Fuel pumps, injectors, lines, tanks, filler necks and evaporative systems, gasoline and diesel, including leaks and fuel smell.
1 recall for this model year involves the fuel system.
If your problem matches, a dealer repairs it free under the recall.
Complaints11
Typical mileage88k
Crashes / fires0 / 2
Injuries0
Parts named in these complaints
Storage7
Delivery2
Owners choose these labels when they file, so they are a guide rather than a diagnosis.
What owners say
Fuel systemFiled Aug 2017130,000 milesMT
Tl* the contact owns a 1992 Ford F-350. While fueling the vehicle, the fuel was transferring to the rear fuel tank and overflowing. The failure caused fuel to leak out onto the ground. The vehicle was taken to kalispell Ford, in kalispell mt 59901, but the recall had expired. The manufacturer was notified of the failure and informed the contact that the VIN was not included in NHTSA campaign number: 93v125000 (fuel system, gasoline). The approximate failure mileage was 130,000.
Owner complaint 11013487 filed with NHTSA
Fuel systemFiled Jun 200445,000 milesID
The defective check valve within the fuel pump assembly causes a portion of the unused fuel from one tank to be returned to the second tank. When this occurs, the capacity of the second tank CAN be exceeded, causing fuel spill. Spilled fuel CAN result in a fire when exposed to the source of ignition. *ak the consumer contacted the dealer who indicated that the recall had expired and that they would not fix it under the recall.
A malfunctioning check valve within the fuel pump assembly causes a portion of the unused fuel from one tank to be returned to the second tank. When this occurs, the capacity of the second tank CAN be exceeded, causing fuel spillage.
Risk and remedy
Risk
Spilled fuel CAN result in a fire when exposed to asource of ignition.
Remedy
Replacement of the fuel pressure regulator and installation of redundant check valves.